| Availability: | |
|---|---|
| Quantity: | |
GLR-314
E-ABLE POWER
GLR-314
GLR-314 Series | High-Voltage Stackable LFP Module GLR-314 High-Voltage Stackable Battery ModuleA high-voltage DC-coupled LFP battery module — the premier building block for C&I hybrid inverter systems. Each module delivers 16.08kWh with Grade A 314Ah cells, stacking 2–16 modules in series per rack (32–257kWh), with up to 10 racks in parallel for 800kW+ systems. Compatible with Deye, Growatt, Solis, Goodwe, Sol-Ark, SMA, and Victron via CAN/RS485. Modular architecture scales from a single rack to multi-MWh — start small, expand incrementally. | ![]() |
Grade A 314Ah LFP cells deliver 6,000+ cycles at 90% DOD — 15+ years of daily operation. LFP thermal stability (>270 °C) and zero-cobalt chemistry drastically lower TCO for C&I storage applications.
True building-block architecture — 2–16 modules per rack, up to 10 racks in parallel. Start with a single rack for a small commercial site and expand incrementally as demand grows. No stranded capacity, no forklift upgrades.
Validated for DC-coupling with Deye, Growatt, Solis, Goodwe, Sol-Ark, SMA, and Victron. CAN/RS485 plug-and-play BMS handshake avoids proprietary lock-in. E-Able Power validates compatibility and provides recommended module arrangement per inverter.
| Category | Parameter | Specification |
|---|---|---|
| General | Model / Product Type | GLR-314 / High-Voltage Stackable LFP Module (Rack-Mounted) |
| Topology | DC-Coupled High-Voltage Architecture — Series Stackable | |
| Application | C&I Peak Shaving, Microgrid, Backup Power, Solar Self-Consumption, EV Charging | |
| Battery System | Cell Chemistry | Grade A LiFePO4 (LFP) — 3.2V / 314Ah Prismatic Cells |
| Module / Rack Capacity | 16.08 kWh per Module / 32.16 kWh (2S) to 257.28 kWh (16S) per Rack | |
| DC Voltage Range | 102.4 Vdc (2S) to 819.2 Vdc (16S) — Customizable per Inverter | |
| Cycle Life / DOD | ≥ 6,000 Cycles at 25°C, 0.5C, 90% DOD | |
| Integration | Compatible Inverters | Deye, Growatt, Solis, Goodwe, Sol-Ark, SMA, Victron (Confirm with Order) |
| Communication | CAN 2.0 / RS485 / RS232 — Modbus RTU, BMS-to-Inverter & BMS-to-EMS | |
| Physical | Module Dimensions / Weight | 838 × 478 × 278 mm / 125 kg per Module |
| Ingress / Installation | IP20 / Stackable Rack with Castor Wheels — Indoor | |
| Warranty | 5 Years Standard / 6,000 Cycles — Project-Specific Extensions Available | |
Table 1.0 — GLR-314 technical specifications. Module count, DC bus voltage, and inverter platform confirmed per project. IEC 62619 cell certification. 10-rack parallel maximum for 800kW+ system capacity.
Reduce demand charges by discharging during peak tariff windows.
Critical UPS backup with high-voltage DC efficiency.
Buffer rapid chargers to mitigate grid impact and upgrade costs.
Scalable energy autonomy for remote farming operations.
Unlike fixed-capacity all-in-one cabinets, the GLR-314 is a true building-block platform: start with a single module (16.08kWh) on a 2-module rack (32kWh) and expand incrementally — add modules to the same rack (up to 16 modules, 257kWh) and add parallel racks (up to 10 racks, 2.57MWh total). This modularity eliminates two common problems: (1) stranded upfront capital — you only buy capacity you need today, and (2) forklift upgrades — capacity expansion is additive, not replacement. Each module is identical and interchangeable, simplifying spare-parts inventory and field service.
GLR-314 modules are validated with leading C&I hybrid inverters: Deye, Growatt, Solis, Goodwe, Sol-Ark, SMA, and Victron. Communication via CAN/RS485 with Modbus RTU ensures plug-and-play BMS-to-inverter handshake — no proprietary protocols, no vendor lock-in. Before order, provide your inverter model and DC voltage window. E-Able Power engineering validates compatibility, recommends the optimal module series/parallel arrangement for your inverter's MPPT range, and includes the validation report in the technical proposal (2–3 business days).
The GLR-314 is fully configurable. Options subject to project volume: module count per rack (2–16), DC bus voltage configuration per inverter spec, number of parallel racks (up to 10), rack customization (castor wheels, enclosure color, OEM labeling), and communication protocol selection. Multi-rack systems include DC combiner box design and system-level BMS coordination as part of the engineering package. 5-year standard warranty with extension options available.
Installation: indoor battery room with level floor, adequate ventilation per local code, and minimum 1m clearance for service access. Racks include castor wheels for positioning — no crane or forklift required for individual modules (125kg each). DC cabling from rack busbar to inverter location. Maintenance is near-zero — LFP cells require no equalization, no water, no electrolyte. Annual inspection: BMS SoH data review, module connection torque check, visual inspection of racks. Individual hot-swappable modules — replace a single module without shutting down the entire rack. Remote commissioning support included; on-site engineer available for projects above 500 kWh.
Factory: Dongguan, Guangdong, China. Cells IEC 62619 certified. 5-year standard warranty. Project-specific compliance documentation available on request.
Every GLR-314 system is configured to your inverter and project — module count, DC bus voltage, rack arrangement, and inverter compatibility validated per site. Send your load profile and inverter specifications for a complete technical proposal within 2–3 business days.
content is empty!